Ask any non-NVH related questions about using PicoDiagnostics software here.
-
jcg0324
- Newbie
- Posts: 2
- Joined: Sun Dec 22, 2019 12:50 pm
Post
by jcg0324 »
What is an "extended drop test?"
-
Steve Smith
- Pico Staff Member
- Posts: 1589
- Joined: Sun Aug 25, 2013 7:22 am
Post
by Steve Smith »
Hello and thank you for the post
The PicoDiagnostics Battery Extended Drop test will enable you to extend the measurement capabilities of the standard Pico Battery test.
By adding x1 test leads to Channels C and D, we can measure the voltage drop across the starter motor positive and ground cables respectively
With the Battery Test selected, click on the “Options” tab and tick the box adjacent to “Extended Drop test” and click OK
The connection description can be found below:
- Image 1
Below we have the additional test results after carrying out the Extended drop test
- Image 2
The following links allow you to dig deeper into the PicoDiagnostics Battery Test results and tackle some challenging questions too
post77701.html#p77701
post57461.html#p57461
This forum post will help with additional volt drop techniques using PicoScope
topic11551.html