clay bird thrower

Ask any non-NVH related questions about using PicoDiagnostics software here.
Post Reply
OMAKAUAUTO
Newbie
Posts: 1
Joined: Sat Jan 18, 2020 4:29 am

clay bird thrower

Post by OMAKAUAUTO »

Hi I am currently trying to workout how to workout the average amps on a scope capture i have done.. any help appreciated i have managed to use the measurements and measure the capture but not sure im doing it properly i have attached the file if anyone wants to give it a crack
Attachments
clay thrower.psdata
(1.26 MiB) Downloaded 282 times

ben.martins
Pico Staff Member
Pico Staff Member
Posts: 539
Joined: Tue May 16, 2017 1:02 pm

Re: clay bird thrower

Post by ben.martins »

Hello,

Thank you for your post.

I think what you are trying to achieve can be done by adding a measurement and then selecting the DC average between the rulers. I've attached a short video on how this is done but if this isn't quite what you was hoping for then please let us know and we can discuss further.
Measuring between rulers.mp4
(2.83 MiB) Downloaded 310 times
Kind regards

Ben

Post Reply