Thank you once again to the software teams for their continued dedication to the development of PicoScope 7 Automotive which can be downloaded here https://oem.picoauto.com/p7beta/download

PicoScope 7 version 7.0.71.8005 (scheduled release date 26-04-21)

Further to the introduction of Spectrum mode in PicoScope 7.0.68, the following new features have been included:

Spectrum peak span bin count

Bin count adjustment now included when editing spectrum measurements
• With Spectrum mode selected, click on the “More” button in the left-hand tool panel and select Measurements
• Note: Clicking on the “Star” symbol to the left of the Measurement symbol will place the Measurement button in the left-hand tool panel where it will remain ready for use without having to select “More”
• In the example below we have opted to display the measurement “Amplitude at peak” for channel A within a large measurement panel
• Click on the large measurement panel to reveal further measurement options
• Note the option to adjust the Spectrum peak span bin count is now available
Image 1
Image 1
Please note, when there are no active Scope views present, only measurements applicable to the Spectrum view will be visible and vice-versa (See images below)
Image 2
Image 2
Image 3
Image 3
Image 4
Image 4
Feedback on the design and function of the Spectrum measurement options would be most welcome
Click on More > Send Feedback within the software

Additional harmonic measurement controls

Highest Harmonic, Harmonic Range and Harmonic noise floor controls will now appear if applicable to the selected measurement

• With Spectrum mode selected, click on the “More” button in the left-hand tool panel and select Measurements
• Note: Clicking on the “Star” symbol to the left of the Measurement symbol will place the Measurement button in the left-hand tool panel where it will remain ready for use without having to select “More”
• In the example below we have opted to display the measurement “Total Harmonic Distortion (THD%)” for channel A within a large measurement panel
• Click on the large measurement panel to reveal further measurement options
• Below we now display the controls for Highest Harmonic, Harmonic Range and Harmonic noise floor
Image 5
Image 5
Bug Fixes

Improvements to the layout & spacing of the UI controls for Mac users
Improved 8 channel device support across all platforms

On the horizon

J1939 Serial Decoder
Signal Generator controls for PicoScope 4823

I hope this helps, take care.......Steve