Hi
Are there scopes that display the secondary ignition pattern (with waste spark) which provide a split screen showing the power spark in one and the waste spark in another "under each other" at the same vertical line for easy of reading?
I have pico scope model 4423 running software version 6.14.25, will that do it, or I need another software or/and hardware?
Using the Views tool you can "Auto arrange" the axis of 4 channels as below where we have 4 x secondary ignition events from a wasted spark ignition system
Image 1
You can also use View per channel where you can take advantage of individual measurement controls for each view
Image 2
In addition to View per channel you can then drag these viewports to suit your screen size or desired preference
Image 3
Using zoom you can then focus on each chosen ignition event in greater detail
Image 4
Using a trigger on number 1 secondary ignition signal will help to stabilize the view whilst also provide the relevant synchronization from which to "time" and identify additional ignition events
More information and videos on the various viewing modes can be found here topic22097.html
Steve, thanks for the viewports ideas. I will give those methods a try.
samjesse, looks like Steve's suggestion will work depending on how many cylinders you need to capture. I was going to suggest the Pico Mixmaster PP361 with 3 channels deployed: CHA with an inductive sync probe or MI074 Secondary 10,000:1 lead; CHB connected to positive firing events; CHC connected to negative firing events(inverted). The number of MI074's needed depends on the number of cylinders.