Search found 48 matches

by tode
Tue Sep 09, 2014 7:14 pm
Forum: PicoScope 6 Automotive software
Topic: PicoScope Beta 6.9 Waveform Library Browser
Replies: 81
Views: 387585

Re: PicoScope Beta 6.9 Waveform Library Browser

Ok, I understand. Great system, very well done.
by tode
Sun Sep 07, 2014 6:27 pm
Forum: PicoScope 6 Automotive software
Topic: PicoScope Beta 6.9 Waveform Library Browser
Replies: 81
Views: 387585

Re: PicoScope Beta 6.9 Waveform Library Browser

If possible, I wanted to ask how to tell if the upload of the waves, from my PC, are completed successfully, I have had several problems with three different PCs even if the files were only 6 Mb upload could not do, now I uploaded a single waveform with 500Kb of space and I've had no error messages ...
by tode
Sat Sep 06, 2014 8:00 am
Forum: Diagnostic discussion
Topic: dont understand this lambda pattern
Replies: 4
Views: 7926

Re: dont understand this lambda pattern

If the sensor has only one wire you can just connect to battery negative or chassis, but if the oxygen sensor has four wires, two heating, one signal, one is an electronic mass, where the unit cleans the signal with the electronic filters, the signal that appears with the Pico is the one that also r...
by tode
Fri Sep 05, 2014 7:25 pm
Forum: Diagnostic discussion
Topic: Subaru Forester oxygen sensor readings
Replies: 5
Views: 17432

Re: Subaru Forester oxygen sensor readings

i know that the target of the discussion is to use the Pico to control the oxygen sensor to broadband, but I think the best way is to use the diagnostic tester with software eobd, in real values, "current pump" where the ECU shows the values ​​in mA, in phases cutoff (much oxygen) or polluting the i...
by tode
Thu Sep 04, 2014 7:42 pm
Forum: Diagnostic discussion
Topic: dont understand this lambda pattern
Replies: 4
Views: 7926

Re: dont understand this lambda pattern

Hello "jmolnar," I try to give an answer .... the oxygen sensor, which thou hast made the measurement is installed on a vehicle that meets an old anti-pollution legislation, which allows more emissions, a sensor so slow is not a big problem at least until the idle speed does not fluctuate according ...
by tode
Sat Aug 30, 2014 4:56 pm
Forum: PicoDiagnostics NVH
Topic: NVH sensor which use?
Replies: 26
Views: 68834

Re: NVH sensor which use?

I was observing this tool, it seems very interesting, I noticed that only has one input, which connect either the accelerometer or microphone, in that occasion you should use one or the other? Would not it be useful to be able to connect both sensors?
Thanks
by tode
Tue Jul 29, 2014 8:08 pm
Forum: Diagnostic discussion
Topic: WPS500X Pressure transducer back leakage tests
Replies: 27
Views: 45541

Re: WPS500X Pressure transducer back leakage tests

Very interesting these tests and I also agree on the fact that for any system changes the response of the system, the injector type, the length of the tube back, the presence of pressure regulators, if you use HP pump with 3 pistons, the variables increase if pumps are used in one or two pistons (Bo...
by tode
Fri Jun 20, 2014 7:00 pm
Forum: Introductions
Topic: Presentation
Replies: 1
Views: 3958

Presentation

A salute to the whole community, are a mechanic from Italy, some from a year I have the tool of Pico four-channel, I find it very good by comparing it with the Bosch motortester which use for several years. A compliment to those who manage the forum, which has a very high technical level, hard to fi...