Thank you for the continued feedback. I think the best course of action is to uninstall your software once again and delete the PicoScope6 Automotive folder from the Program files (x86) folder on your hard drive C:\Program Files (x86)\Pico Technology\PicoScope6 Automotive (is a typical a file path) ...
Thank you for the feedback. The does sound like "Connectivity" given we cannot use Pico Diagnostics either. Just reading your first post, I read " After the upgrade , install the new version of PicoScope 6 Automotive 6.14.5." Could you confirm if the PC/Operating system was updated/reformatted etc. ...
Following on from Ben’s excellent forum post here https://www.picoauto.com/support/topic22135.html I wanted to share the noise cancelling feature of another audio software suite called Audacity which can be downloaded here https://www.audacityteam.org/download/ Ben has referred to Sonic Visualizer (...
Hello and thank you for the post, sorry for the late reply. The maximum input voltage for an RPM signal using Channel D (NVH) is 20 V This raises an issue when using an inductive sensor (for example, Crank) as your speed input, given the crank sensor voltage may well increase above 20 V as RPM incre...
Hello and thank you for the post, your English is fine and I understand the concern we are having Sorry for the late reply too Could you confirm there are no other PicoScope 6 Automotive versions such as beta on your PC? They should be fine but to help with resolving this issue we should remove them...
Hi Barry, could you check you have PicoScope 6 Automotive installed and not PicoScope 6 Test and Measurement. The Automotive version is found here The following link will help with activation
Hello and thank you for the post The collection time of data and display refresh rate should not be influenced by the frequency of the signal to the extent it appears in your second video Whist the display appears to update at a reduced rate, could you confirm the data was collected and saved correc...
Hello and thank you for the post The scale for measurement of acceleration with our NVH software is linear for mg and m/s2 We also have the option to change the units to dBg (log scale) if required ADVANCED OPTIONS.png Using the linear scale, 20 mg is double the vibration level of 10 mg assuming the...