what is it

Post by Autonerdz »

Looks like a negatively controlled saturated injector driver with the scaling wrong. Looks like a 20:1 attenuator is attached but PicoScope has not been told that it's there so the 14v circuit shows at .7v.

You will find the 20:1 selection under Settings/Probes. The way it is scaled from 0 to 1v (0 to 20) the injector kick is off the top of the screen. This is normally up to 80 volts. Select the 20:1 and then choose the +- 5v range to scale the screen to +-100 volts (with attenuator in place). Then you will see it all scaled correctly.
Tom Roberts
(The Picotologist)
Autonerdz

RobOnestop
Newbie
Posts: 5
Joined: Sat Nov 11, 2006 7:35 pm
Location: east sussex

Post by RobOnestop »

believe it or not its what i got from a lambda sensor
Mobile Mechanic Specialising in
Auto diagnostics & Car Electrics

User avatar
Autonerdz
TwoWaves
TwoWaves
Posts: 387
Joined: Wed Nov 20, 2002 4:19 pm
Location: Washington State USA

strange

Post by Autonerdz »

OK, you had me fooled. That's a classic injector pattern. You even have increasing voltage drop as the current rises. A bit noisy is all.

You need to increase the voltage scale and put some more time on the screen to get a few cycles in view and see the whole pattern. Could be some kind of pulsed O2 heater control. I don't have any info here on your application.
Tom Roberts
(The Picotologist)
Autonerdz

RobOnestop
Newbie
Posts: 5
Joined: Sat Nov 11, 2006 7:35 pm
Location: east sussex

Post by RobOnestop »

ive not had pico long so still finding my feet
whats the best setting for zirconia lambdas time base
Mobile Mechanic Specialising in
Auto diagnostics & Car Electrics

User avatar
Autonerdz
TwoWaves
TwoWaves
Posts: 387
Joined: Wed Nov 20, 2002 4:19 pm
Location: Washington State USA

setup

Post by Autonerdz »

You need lots of time on the screen to see the O2 cycles. Here is an example series at 1s/div:

http://www.autonerdz.com/cgi/yabb2/YaBB ... 1114921447

These are standard Zirconia sensors pre and post CAT.