WPS500X Zoom delay

Post by FioranoCars »

Hi
Bit of a weird set of technical questions ...
When using the 100Hz filter/Zoom feature is there any delay/time lag to the data?

Would a step change in base pressure level create a small lag in this, or a judder in the output? Or render it useless?

Is there a range of pressures where using zoom gives poor results, ie the base line must be within x% for zoom to be workable?
ie a pressure that is pumped to say 25bar and falls to 10bar before re-pumping would make the zoom pointless?

Looking at a couple of scenario's and realise that zoom could cause more issues if we don't understand the feature fully.

Anything in terms of feedback would be great!

thanks
Richard Lukins
FioranoCars.com

PicoPhil
Pico Staff Member
Pico Staff Member
Posts: 71
Joined: Thu Dec 23, 2010 11:38 am

Re: WPS500X Zoom delay

Post by PicoPhil »

Hi Richard
What version software are you using ? Sorry for the late reply We have all been to various parts of Europe and all out at Automechanika Frankfurt next week. Does this happen on all ranges ?
Thanks
Phil R

User avatar
FioranoCars
TwoWaves
TwoWaves
Posts: 386
Joined: Thu Dec 13, 2012 11:26 am
Location: London, UK

Re: WPS500X Zoom delay

Post by FioranoCars »

Hi Phil
Forgot about this, it was a while ago!

It was more of a hardware than software question, but using current version of software, and the question was not due to seeing something we'd done, more what we might need to avoid for unreliable or unpredicted results (and the time spent tracking down our stupidity!) :D

I think the answer lies in the method of filtering (Zooming) in the WPS500X, and in all likelihood the delay will be meaningless/negligible if any?

So the only question is related to step changes in pressure so where the system being measured moves from say 45bar to 38 bar quickly, as to how that would be shown on the trace, before re-establishing a zoom at the new pressure level ...?

Odd questions I know, but hey, someone has to be odd :oops:

Thanks
Richard

User avatar
FioranoCars
TwoWaves
TwoWaves
Posts: 386
Joined: Thu Dec 13, 2012 11:26 am
Location: London, UK

Re: WPS500X Zoom delay

Post by FioranoCars »

Hi Phil R
Bump!

Richard
PS Will you chaps be over at Sandown next month?