I made a cylinder balance test by PicoDiagnostics software (comes with PicoScope6 version: 6.6.16.12
).Channel B pluged in ignition signal as trigger. My PicoScope is 4223.
But I cann't see the trigger signal and speed curve. I think that something must be wrong in the software. And notice this problem of previous version have been discussed in other thread here.
Attached my files here.
And how to understand the blue bar for variation ? Does the blue bar longer, then the cylinder contribute more ? Can somebody make a detail interpretation for me ?
I would suggest updating to R6.6.28 which is labelled as the Release Candidate on our website http://www.picoauto.com/software.html to resolve your missing traces.
The blue bar for variation is currently just showing the min and max values for each cyclinder, I believe this functionality may be expanded in the future.