PicoScope 7 Automotive
Available for Windows, Mac, and Linux, the next evolution of our diagnostic scope software is now available.
PicoScope 4823
The 4823 is the world’s first high-speed, high-resolution, 8-channel automotive oscilloscope, and is fast enough for CAN, CAN FD, and FlexRay including serial data decoding. It is ready-configured for automotive probes and includes more than 150 Guided tests, plus access to thousands of comparisons in the Pico waveform library which now supports 8 channels.
This table lists the specifications that are most important to the average customer using the PicoScope for automotive diagnostics. If you have a more specific use for the product (or are just curious), detailed specifications are below this table.
Key specifications at a glance | |
---|---|
Model | PicoScope 4823 |
Channels | 8 |
Bandwidth | 20 MHz |
Resolution | 12 bits (16 bits enhanced) |
Sampling rate | 80 MS/s (1-4 channels in use) 40 MS/s (5-8 channels in use) |
Buffer memory | 250 M samples |
Input ranges (full scale) | ±10 mV to ±50 V in 12 ranges |
Software supplied | PicoScope®, PicoDiagnostics® |
Language support | Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish |
PC and power requirements | Desktop or laptop running Windows 10 (recommended) Powered from PC USB port (USB 3.0 / 3.1 recommended; USB 2.0 compatible). |
Some of our customers use our automotive oscilloscopes for vehicle design and development and other non-diagnostic purposes. For these customers we have provided detailed technical specifications.
Oscilloscope specifications (vertical) | |
---|---|
Model | PicoScope 4823 |
Bandwidth | 20 MHz (50 mV to 50 V ranges) 10 MHz (10 mV and 20 mV ranges) |
Channels | 8 |
Vertical resolution | 12 bits |
Enhanced vertical resolution | 16 bits |
DC accuracy | ±1% of full scale ±300 μV |
Input Sensitivity | 2 mV/div to 10 V/div |
Input ranges (full scale) | ±10 mV to ±50 V in 12 ranges |
Input characteristics | 1 MΩ in parallel with 19 pF |
Input type | BNC |
Input coupling | Software selectable AC/DC |
Overvoltage protection | ±100 V (DC + AC peak) |
Oscilloscope — horizontal | |
---|---|
Maximum sampling rate 1-4 channels in use 5-8 channels in use |
80 MS/s 40 MS/s |
Maximum sampling rate (USB streaming) | 20 MS/s (USB 3.0) 10 MS/s (USB 2.0) |
Buffer memory | 250 M samples |
Waveform buffer | Up to 10,000 waveforms |
Timebase ranges | 100 ns/div to 5000 s/div |
Dynamic performance (typical) | |
---|---|
Crosstalk | 76 dB, DC to 20 MHz |
Harmonic distortion | < −60 dB |
SFDR | > 60 dB |
Noise | 220 μV RMS on 50 mV range |
Bandwidth flatness | DC to full bandwidth (+0.25 dB, −3 dB) |
ADC ENOB | 11.3 bits |
Signal generator | |
---|---|
Standard output signals | Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half-sine, white noise, PRBS |
Standard signal frequency | DC to 1 MHz |
Sweep modes | Up, down, dual |
Triggering | Can trigger a counted number of waveform cycles or sweeps (up to 1 billion) from the scope trigger or manually from software. |
Frequency accuracy | ±20 ppm |
Frequency resolution | < 20 MHz |
Voltage range | ±2 V |
Amplitude and offset adjustment | Signal amplitude and offset within ± 2V range. |
DC accuracy | ±1% of full scale |
Output characteristics | Rear-panel BNC, 600 Ω output impedance |
Overvoltage protection | ±10 V |
Arbitrary waveform generator | |
---|---|
Update rate | 80 MS/s |
Buffer size | 16 kS |
Resolution | 14 bits |
Triggers | |
---|---|
Source | Any input channel |
Basic triggers | Auto, repeat, single, none |
Advanced triggers | Rising edge, falling edge, edge with hysteresis, pulse width, runt pulse, dropout, windowed |
Maximum pre-trigger delay | Up to 100% of capture length |
Maximum post-trigger delay | Up to 4 billion samples |
Spectrum analyzer | |||||
---|---|---|---|---|---|
Frequency range | DC to 20 MHz | ||||
Display modes | Magnitude, average, peak hold | ||||
Windowing functions | Rectangular, Gaussian, triangular, Blackman, Blackman-Harris, Hamming, Hann, flat-top | ||||
Number of FFT points | Selectable from 128 up to 1 million in powers of 2 | ||||
Scale / units | X axis : linear or log 10 Y axis : logarithmic (dbV, dBu, dBm, arbitrary) or linear (volts) |
Math channels | |
---|---|
General functions | −x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, derivative, integral, delay |
Filter functions | Low pass, high pass, band stop, band pass |
Graphing functions | Frequency, duty cycle |
Multi-waveform functions | Min, max, average, peak |
Operands | Input channel, reference waveforms, time, constants, pi |
Automatic measurements | |
---|---|
Scope mode | AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak to peak, rise time, rising rate. |
Spectrum mode | Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD+N, SFDR, SINAD, SNR, IMD |
Statistics | Minimum, maximum, average and standard deviation |
Serial decoding | |
---|---|
Protocols | CAN, LIN, I²C, UART/RS-232, SPI, I²S, FlexRay, CAN FD |
Inputs | All input channels with any mixture of protocols |
Mask limit testing | |
---|---|
Mask generation | Auto generate from captured waveform, manual drawing, manual coordinate entry |
Actions | Highlight on screen, select in buffer overview, activate alarm |
Statistics | Pass/fail, failure count, total count |
Alarms | |
---|---|
Initiating events | Capture, buffer full, mask fail |
Alarm actions | Beep, play sound, stop/restart capture, run executable, save current buffer/all buffers, trigger signal generator |
Data export | |
---|---|
Output file formats | BMP, CSV, GIF, JPG, MATLAB 4, PDF, PNG, PicoScope data, PicoScope settings, TXT |
Output functions | Copy to clipboard, print |
Environmental | |
---|---|
Operating environment Temperature range Humidity |
0 °C to 40 °C (20 °C to 30 °C for quoted accuracy) 5% to 80% RH, non-condensing |
Storage environment Temperature range Humidity |
–20 to +60°C 5% to 95% RH, non–condensing |
Physical dimensions | |
---|---|
Dimensions | 190 x 160 x 40 mm (approx 7.5 x 6.3 x 1.6 in) |
Weight | < 550 g (approx 1.2 lb) |
Software | |
---|---|
Software included | PicoScope 6 oscilloscope software with waveform database and guided tests. PicoDiagnostics software |
Languages | Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean*, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish |
For Korean software, please contact our Korean distributor VNP InterBiz
General | |||||
---|---|---|---|---|---|
Additional hardware (supplied) | USB cable, user manuals | ||||
PC requirements | Desktop or laptop running Windows 10 recommended (read more) |
||||
PC connectivity | Powered from PC USB port (USB 3.0 / 3.1 recommended, USB 2.0 compatible). | ||||
Power requirements | Powered from USB ports | ||||
Safety approvals | LVD compliant | ||||
EMC approvals | Tested to meet EN61326-1:2006 and FCC Part 15 Subpart B | ||||
Environmental approvals | RoHS and WEEE compliant | ||||
Total satisfaction guarantee | In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days. | ||||
Warranty | 2 years |
When operated in the presence of high EM fields, interference in the form of additional measurement noise may be experienced. This is no cause for concern but the user should endeavour to minimise any adverse effects so caused through careful positioning when in use and/or not operating within close proximity of potential sources of interference such as mobile telephone transmitters, antenna masts, etc.