PicoBNC+ 2000 A AC/DC current clamp

The 2000 A current clamp allows you to measure up to 2000 amps without cutting, or disconnecting or stripping wires. Simply clamp the jaws around the cable to be tested and plug the clamp into your PicoScope.

The TA388 has a specification to match our popular TA167 200A/2000A clamp but fitted with a PicoBNC+ interface. The clamp can be auto-configured by PicoScope software when connected to the scope. Ranging is carried out automatically with no user switching required. The clamp is powered via the scope and therefore does not require any batteries. Additionally, the clamp is auto-zeroed whenever connected to the scope.

These current clamps have been designed for use with PicoScope oscilloscopes and feature additional screening to reduce noise pickup. The Pico TA388 current clamp can either be purchased as an accessory within one of our popular diagnostic kits or individually but requires a PicoScope featuring the PicoBNC+ such as the 4225A or 4425A.

In stock. Available for despatch.
£232
TA388

Typical Uses

The wide range of this clamp allows currents from under 1 A right up to 2000 A to be measured. It can be used with a PicoScope for many applications including:

  • Battery testing with PicoDiagnostics software
  • Relative compression testing
  • Starter motor testing
  • Alternator output testing
  • Hybrid and EV electric motor current

The 2000 A clamp also features auto-ranging allowing the TA388 to be used many applications where a "low amps" clamp would normally be required such as checking injector and ignition current.

Specifications

Attribute Published specification
Model PicoBNC+ current clamp: 2000 A AC/DC
Physical  
Combined length of lead and probe 2.85 m
Jaw size 32 mm diameter
Weight 320g
Electrical  
Working current range ±2000 A DC or AC peak
Overload current 2200 A DC (for one minute)
Maximum voltage and CAT ratings 300 V
Hardware bandwidth 20 kHz
Temperature coefficient ±0.1% of reading / °C
Hardware Resolution ± 100 mA up to 200 A
± 500 mA above that
Accuracy 1% ± offset up to 1500 A
5% from 1500 A to 2000 A
Operating Temperature range 0 °C to 50 °C
Storage temperature range –20 °C to +85 °C
Operating humidity 15% to 85% (non-condensing)
Bandwidth Frequency range DC to 20 kHz (–1 dB)
Calibration / zero offset requirements On startup