Bosch LSU 4.2 oxygen sensor switching
The purpose of this test is to evaluate the response of a Bosch LSU 4.2 O2 sensor (Pre-Catalyst) in relation to the air/fuel ratio. The correct operation of the O2 sensor is dependent upon the internal heating element, the mechanical condition of the engine, fuel quality, engine temperature, and the integrity of the engine management system.
How to perform the test
- Use manufacturer's data to identify the pump cell circuit at the Oxygen sensor
- Connect x1 blue test lead to PicoScope Channel A, with signal to the Oxygen sensor terminal 6 (Typically a Red wire) and ground lead to the vehicle battery negative terminal, or chassis ground
- Ensure the engine is at it's normal operating temperature
- Start the engine and let it idle
- Start the scope to see live data.
- Start the engine and ensure at operating temperature; with a stable idle speed, rapidly open and close the throttle and allow the engine to return to idle.
- With your waveforms on screen stop the scope.
- Turn off the engine.
- Use the Waveform Buffer, Zoom and Measurements tools to examine your waveform.
Further guidance
Excessive high frequency noise may be present on the captured waveform during the warm up period of the O2 sensor. This is an operational characteristic and not a fault. In order to minimise the acquired noise level, it is advisable to activate Bandwidth Limit prior to testing the LSU 4.2 Oxygen Sensor. Click on Channel A lozenge and select “20 kHz” within the “Vertical” tab (Not applicable to PicoScope 4223 or 4423 models).
In addition to Bandwidth limit, a “Low pass filter” can be applied to the waveform (post capture) by clicking on the channel A lozenge and the DSP tab. Refer to the A-Z of PicoScope for more information.
Modern emission regulations have forced tighter control of engine management systems throughout all engine speed and load ranges. The traditional O2 sensor could accurately detect the stoichiometric air fuel ratio at 14.7:1 petrol (Lambda 1.0) within a very narrow band with an output of approximately 450 mV. The demand for increased accuracy, faster response times and reliability has seen the redevelopment of the Narrow Band oxygen sensor to the industry standard O2 sensor utilised today across all manufacturers, the “Wideband” O2 sensor
The Wideband O2 sensor is often referred to as a Broadband sensor or Air Fuel Ratio sensor (AFR sensor) and can be installed to both petrol / diesel engine vehicles.
The name “Broadband” is derived from the sensors ability to accurately detect the air fuel ratio across a broad or wide spectrum from 10:1 to 20:1 (20:1 being ambient air).
Using the test procedure above will confirm “activity” from the O2 sensor and switching of the pump cell voltage in response to a change in fuelling conditions during WOT and Overrun. The response to acceleration and deceleration of the engine should be near instantaneous confirming the O2 sensor response time to be efficient.
Should you suspect a fault with the switching of LSU 4.2 Oxygen sensor, we have an additional Guided Test to evaluate the entire Oxygen sensor system. Select Guided Tests > Sensors > Oxygen > Oxygen (broadband, Bosch LSU 4.2).
Symptoms associated with a faulty Oxygen sensor:
- Engine Stalling
- Erratic running
- Poor acceleration
- Increased fuel consumption
- Erroneous emission values (4-Gas test)
- Sulphur smell emitted via exhaust
- Malfunction Indicator Lamp (MIL) illumination
- Diagnostic Trouble Codes (DTCs)
Related failures are:
- Discrepancies in the Oxygen sensor switching signal could also be attributed to:
- Misfire caused by mechanical or electrical systems
- Contaminated fuel
- Excessive engine wear/oil consumption
- Physical damage to Oxygen sensor tip
- Fuel system too rich or lean
- Thermal shock
Disclaimer
This help topic is subject to changes without notification. The information within is carefully checked and considered to be correct. This information is an example of our investigations and findings and is not a definitive procedure. Pico Technology accepts no responsibility for inaccuracies. Each vehicle may be different and require unique test settings.