Negative priming fuel pressure (diesel)
The purpose of this test is to verify the integrity of a fuel supply system (vacuum type) by checking its ability to create and maintain negative pressure (i.e. a pressure below atmospheric pressure).
How to perform the test
- Connect the sight block, with the stop tap downstream, in series between the fuel filter assembly and the fuel supply hose leading to the tank.
- Connect a hand primer bulb upstream of the sight block (or use a built-in equivalent, if available) and prime the diesel circuit.
- Close the stop tap.
- Remove the hand primer bulb and secure all connections.
- With its inlet port open to the atmosphere, switch on the WPS500X and wait for the calibration to complete (the LEDs will flash through ranges 1 to 3 and back to 1).
- Connect the WPS500X to the sight block and PicoScope Channel A and select Range 2.
- Reopen the stop tap.
- Connect the hand primer bulb to the WPS500X bleed port and, whilst pressing the WPS500X bleed button, prime the WPS500X until all air is purged, then release the bleed button.
- Start the scope.
- Start and run the engine.
- With the engine at a stable idle speed, close the stop tap up until the engine is about to stall and then reopen it.
- Wait for the engine to return to a stable idle speed, then switch it off.
- Stop the scope.
- Use the Waveform Buffer, Zoom and Measurements tools to examine your waveform.
Further guidance
With the fuel supply system suitably primed and the engine off, a small negative pressure should remain in the system. However, if the hoses, connections, or pump internals are leaky, air will enter the system causing the pressure to return to atmospheric pressure (0 bar) and the fuel to drain back to the tank. This behaviour is similar to keeping your finger over the end of a straw full with fluid: the fluid will remain in the straw while a good seal is maintained between finger and straw.
With the engine running, the fuel pump should be able to create and maintain constant negative pressure. Any tendency to return to 0 bar (atmospheric pressure) indicates that either the pump is faulty or air is being drawn in to the system.
By closing the stop tap, we are maximally loading the system. If the pressure does not drop significantly during these test conditions, there is an air leak or pump fault.
A blockage in the fuel filter or upstream of the sight block will reduce the measured vacuum during steady state running conditions.
In any of the cases above, where the measured pressure is greater than expected (i.e. less vacuum), the sight block can be used to check for fuel contamination, color and whether air is being drawn into the system. If there are no upstream blockages and the fuel is of the correct type, quality and without contamination or air ingress, then the fuel pump may be unserviceable and require inspection.
The test steps above may be performed without closing the stop tap so as to check the negative fuel pressure (vacuum) at idle (or at other engine loads and speeds) against manufacturer specifications: refer to manufacturer data for specific test conditions and results.
Symptoms of faulty negatively primed fuel supply systems are:
- Non-start, difficulty starting or excessive cranking.
- Erratic idle or running when under constant load.
- Hesitation or performance issues under high loads.
Note that negatively primed systems do not tend to show external signs of leakage as they tend to draw air in rather than push fuel out.
When diagnosing suspected faults in diesel systems, always check fuel for quality and contamination using dedicated processes and equipment.
Please check these videos for further information:
Sight Block Kit video
Frank Massey Common Rail Pressure Sensor Testing
Disclaimer
This help topic is subject to changes without notification. The information within is carefully checked and considered to be correct. This information is an example of our investigations and findings and is not a definitive procedure. Pico Technology accepts no responsibility for inaccuracies. Each vehicle may be different and require unique test settings.