Further guidance

A number of pump types are available for use within hydraulic systems; gear, piston and vane. Irrespective of the pump type, their job is the same; to maintain fluid flow in opposition to the circuit flow resistance. Pressure is the result of the resistance to the flow and hydraulic pumps are designed to maintain a set flow rate up to a specified system pressure, which is set by a relief valve within the system. If insufficient pressure is generated within the system, we must examine the possible flow pathways because hydraulic oil, much like electricity, will take the path of least resistance. Such pathways might arise from failures within hoses, coupling, seals, and valves etc.
The WPS600C is a fast responding pressure transducer capable of measuring the ripple generated by a hydraulic pump. This is particularly useful when working with piston pumps as we can see the effect each piston is having in generating flow within the hydraulic circuit. To maximise the size of the ripple we can deadhead a service, which increases the system pressure to full pressure and puts the pump under maximum load. Any weakness in a piston is more likely to show up under these conditions.
Piston pumps typically have 9 or 11 pistons. When analysing the pressure waveform, zoom into the peak pressure parts and look for the repeating pattern. Some slight variations are acceptable as the pressure is affected by everything happening upstream in the hydraulic circuit, meaning it can change due to relief valve operation, spool position, changes in flexible pipework volumes, etc. However, by and large, the pattern should be relatively consistent and not show any excessive dropouts.
Differences between ripple waveforms become more obvious when two similar pumps are compared directly, as seen in the waveform capture above. The capture was taken from a machine with two pumps functioning at the same time to support a particular service. It is clear from the differences in the ripple patterns that the two pumps are not operating in quite the same way. Both pumps produce a consistent ripple pattern with even amplitudes within each waveform; however, those amplitudes are bigger in one waveform compared to the other. This suggests the pistons in both pumps are fine but one pump may have more internal leakage than the other, or there are further problems downstream of the pressure transducer.
Another, similar, technique is to capture and use Reference waveforms to profile a pump over a period of time and better understand the changes occuring between services and offer some prediction of the possible time before component failure.
If the number of pistons is unknown but you know the actual engine speed (e.g. from a rev counter onboard the machinery), you can use the Rulers overview to search for the ripple peaks that are separated by one full engine revolution. To do this, set one ruler at a ripple peak and a second ruler at a subsequent ripple peak that gives the same RPM value in the Rulers overview as the actual engine speed. You can then count the number of ripple peaks between them to determine the number of pistons within the pump. Note this technique assumes a 1:1 ratio between engine speed and pump speed. If the pump is geared relative to the engine then the appropriate ratio should be factored in.
With two WPS600Cs available, you can measure the delta P (pressure differential) across a component, such as a motor. This technique is extremely useful for diagnosing internal leakage faults without a flow meter. This is achieved by connecting one WPS600C on the inlet (high pressure side) and the other on the outlet (low pressure side). If you are measuring across a bidirectional motor, the high and low pressure sides will swap as required by its operation. Once the two pressure waveforms have been captured you can use a Math channel to subtract the outlet pressure measurement from the inlet pressure measurement to give the pressure drop across the component.