Automotive Guided Tests

Our PicoScope Automotive software contains over 160 guided tests and includes example waveforms and scope settings. These waveforms were captured using a PicoScope Automotive Diagnostics Kit, find out more about our kits here.  

Home

Heavy-Duty/Off-Highway

Electronically controlled unit injectors

The purpose of this test is to evaluate the operation of a unit injector by observing the voltage and current required to actuate its needle control valve. The test setup also can be used to evaluate the unit injector spill control valve operation.

Warning icon (exclamation mark in circle)

This test involves measuring a potentially hazardous voltage.

Risk of damage to equipment and property, and risk of electric shock, personal injury, or death.

  • Always follow manufacturers' safety instructions and working practices.
  • Ensure the equipment and accessories have a voltage rating that meets or exceeds the possible test voltages.
  • Use suitable attenuating test leads or accessories to avoid damaging your scope.
  • When using BNC accessories, adjust the probe setting in the PicoScope software to apply the appropriate attenuation scaling to your measurements.

How to perform the test

  • Ensure the engine is stopped.
  • Using manufacturer's data, identify the injector (or its spill valve) control circuits. Where the control circuit wiring passes through an engine rocker cover it may be easier to access the wiring at the Electronic Control Module (ECM) harness.
  • Connect a test lead to Channel A and the switched positive side of the control circuit.
  • Connect a test lead to Channel B to the switched negative side of the control circuit.
  • Connect a low amps clamp to Channel C and the control circuit.
  • Start the engine.
  • Start the scope to see live data.
  • With your live waveform on screen, stop the scope and if needed switch off the engine.
  • Use the Waveform Buffer, Zoom and Measurements tools to examine your waveform.

Example waveform

Further guidance

GuideGuide

Unit injectors have long been used within heavy duty diesel engines because the technology helped deliver improved fuel efficiency and power. However, their popularity has declined as Vehicle Manufacturers (VMs) look for the gains available from newer fuel injection technologies, such as the common rail systems used in the automotive industry.

Unit injectors remove the need for the high pressure fuel pumps found in pump-based or common rail fuel systems as the fuel injection pressure is created within the injector body itself. However, they use additional external mechanisms (driven by cam lobes, sometimes on a separate shaft, turning at half the speed of the crankshaft) to develop the fuel pressures required for good fuel atomization and combustion. These mechanisms involve a more complicated setup procedure to ensure the injectors work correctly.

Fuel is delivered to the injectors via machined galleries inside the cylinder head. A low pressure fuel pump along with a mechanical pressure regulator ensure there is always an adequate supply of fuel when each injector requires it.

Later unit injector variants have two solenoids rather than one. The additional solenoid drives a spill control valve that regulates the fuel flowing out of the unit injector back to the return system. It is possible to have just spill control valves on some unit injectors but, for more precise fuelling, a needle control valve is required. Typically, the spill valve is always in an open state meaning the fuel can flow around the injector internals and out to the return system to aid injector cooling.

Much like the 4-stroke internal combustion engine cycle, unit injector operation follows a similar pattern of intake, compression, “delivery”, and exhaust. Here the ECM regulates the fuel delivery (i.e. the injection timing and duration) by precisely controlling the needle control valve.

During the injector's compression phase, its internal plunger (a piston) is depressed by the external pressing force of a cam lobe, or push rod acting against a rocker arm. Just as this occurs, the spill control valve is closed, which prevents fuel from leaving the injector. Then, as the plunger continues to be forced down, the fuel pressure within the injector rises. As with conventional injectors, the fuel pressure must rise sufficiently before the needle control valve is opened so that the fuel is atomized correctly when it is delivered to the cylinder.

As with all solenoid-based actuators, the current must be regulated to prevent coil overheating. Therefore, once the solenoid has performed the initial work to open the needle valve, the current can be reduced to a level that is just sufficient to hold it open. The ECM achieves this by regulating the solenoid voltage using Pulse Width Modulation.

Again, as is characteristic of all solenoids, an induced voltage is generated when its magnetic field collapses when the circuit current is switched off. In the voltage waveforms, this is seen as a high voltage spike which then exponentially reduces. As the voltage reduces, you may see a “pintle hump” in the waveform. This helps to identify whether the core of the solenoid has moved back to its original position.

Once the plunger has passed its end of travel, as the cam lobe rotates past its peak, there is no downward force from the rocker arm and the injector spring pulls the plunger back up. As it does so, it draws fuel from the supply gallery into the injector, ready for the whole process to start over. As the fuel supply side is under a higher pressure than the return side and the fuel moves naturally from the supply side to the spill side (i.e. it is not drawn back through the normally open return system).

Due to the fact the spill valve is always in an open position, it is very difficult for these injectors to fail closed making unit injectors tricky to diagnose. In the event of the engine not starting, checking the electrical side of the injector is a relatively non-intrusive test.

To expand on this test you can add in the spill control valve control and current (as per the example above) to visually see the relationship between spill and needle valve control. It shows that the spill valve is actuated shut before the needle valve is actuated open (as required for the pressure to increase sufficiently before injection takes place). The time difference between these operations is around 300 μs or 0.000300s, which indicates the required degree of precision in these systems.

Disclaimer

This help topic is subject to changes without notification. The information within is carefully checked and considered to be correct. This information is an example of our investigations and findings and is not a definitive procedure. Pico Technology accepts no responsibility for inaccuracies. Each vehicle may be different and require unique test settings.

`