Further guidance


Unit injectors have long been used within heavy duty diesel engines because the technology helped deliver improved fuel efficiency and power. However, their popularity has declined as Vehicle Manufacturers (VMs) look for the gains available from newer fuel injection technologies, such as the common rail systems used in the automotive industry.
Unit injectors remove the need for the high pressure fuel pumps found in pump-based or common rail fuel systems as the fuel injection pressure is created within the injector body itself. However, they use additional external mechanisms (driven by cam lobes, sometimes on a separate shaft, turning at half the speed of the crankshaft) to develop the fuel pressures required for good fuel atomization and combustion. These mechanisms involve a more complicated setup procedure to ensure the injectors work correctly.
Fuel is delivered to the injectors via machined galleries inside the cylinder head. A low pressure fuel pump along with a mechanical pressure regulator ensure there is always an adequate supply of fuel when each injector requires it.
Later unit injector variants have two solenoids rather than one. The additional solenoid drives a spill control valve that regulates the fuel flowing out of the unit injector back to the return system. It is possible to have just spill control valves on some unit injectors but, for more precise fuelling, a needle control valve is required. Typically, the spill valve is always in an open state meaning the fuel can flow around the injector internals and out to the return system to aid injector cooling.
Much like the 4-stroke internal combustion engine cycle, unit injector operation follows a similar pattern of intake, compression, “delivery”, and exhaust. Here the ECM regulates the fuel delivery (i.e. the injection timing and duration) by precisely controlling the needle control valve.
During the injector's compression phase, its internal plunger (a piston) is depressed by the external pressing force of a cam lobe, or push rod acting against a rocker arm. Just as this occurs, the spill control valve is closed, which prevents fuel from leaving the injector. Then, as the plunger continues to be forced down, the fuel pressure within the injector rises. As with conventional injectors, the fuel pressure must rise sufficiently before the needle control valve is opened so that the fuel is atomized correctly when it is delivered to the cylinder.
As with all solenoid-based actuators, the current must be regulated to prevent coil overheating. Therefore, once the solenoid has performed the initial work to open the needle valve, the current can be reduced to a level that is just sufficient to hold it open. The ECM achieves this by regulating the solenoid voltage using Pulse Width Modulation.
Again, as is characteristic of all solenoids, an induced voltage is generated when its magnetic field collapses when the circuit current is switched off. In the voltage waveforms, this is seen as a high voltage spike which then exponentially reduces. As the voltage reduces, you may see a “pintle hump” in the waveform. This helps to identify whether the core of the solenoid has moved back to its original position.
Once the plunger has passed its end of travel, as the cam lobe rotates past its peak, there is no downward force from the rocker arm and the injector spring pulls the plunger back up. As it does so, it draws fuel from the supply gallery into the injector, ready for the whole process to start over. As the fuel supply side is under a higher pressure than the return side and the fuel moves naturally from the supply side to the spill side (i.e. it is not drawn back through the normally open return system).
Due to the fact the spill valve is always in an open position, it is very difficult for these injectors to fail closed making unit injectors tricky to diagnose. In the event of the engine not starting, checking the electrical side of the injector is a relatively non-intrusive test.
To expand on this test you can add in the spill control valve control and current (as per the example above) to visually see the relationship between spill and needle valve control. It shows that the spill valve is actuated shut before the needle valve is actuated open (as required for the pressure to increase sufficiently before injection takes place). The time difference between these operations is around 300 μs or 0.000300s, which indicates the required degree of precision in these systems.