Automotive Guided Tests

Our PicoScope Automotive software contains over 160 guided tests and includes example waveforms and scope settings. These waveforms were captured using a PicoScope Automotive Diagnostics Kit, find out more about our kits here.  

Home

Electric vehicles

0 V potential

The purpose of the test is to prove that a hybrid or electric vehicle High Voltage (HV) system, cable or electrical component is shutdown and unpowered (i.e. no HV potential differences exist) prior to carrying out any work on it. The test is applicable to both Direct Current (DC) and Alternating Current (AC) HV systems, circuits and components.

Warning icon (exclamation mark in circle)

High Voltage (HV) electrical systems have high voltage cabling, stored electrical energy, retained hazardous voltages, and the potential to affect medical devices.

Risk of damage to equipment and property, risk of electric shock, personal injury, or death, and risk of explosion and fire.

  • Read carefully and understand the hazards and risks described above.
  • Only work on HV systems if you are a qualified technician, have received appropriate type-specific training from a qualified electrician, and hold valid accreditation.
  • Do not work with HV systems if you have been fitted with a pacemaker or other electronic medical devices.
  • Always refer to the vehicle manufacturer’s information sources to identify the actions you must take to prevent danger.
  • Use equipment and accessories in accordance with their safety guides.
  • Always wear appropriate Personal Protective Equipment.

How to perform the test

  • In accordance with the vehicle manufacturer's HV system isolation procedures, isolate and lock off the HV power source and take steps to prevent the system from being restored.
  • Wait the manufacturer specified time for the HV capacitors to discharge.
  • Gain access as required to expose the HV test location.
  • Short circuit the Pico 2-pole tester test-lead points and press the test button. It must respond with a rapidly pulsating audible signal and by illuminating the display with red backlighting.
  • Place the two Pico 2-pole tester probes on the negative and positive terminals of a 12 V battery having known good states of health and charge. The tester must display 12 or 13 V.
  • Place one Pico 2-pole tester probe on the HV negative test location and the other on the HV positive location. The two-pole tester display must remain blank.
  • Place one Pico 2-pole tester probe on the HV positive test location and the other on the chassis ground. The two-pole tester display must remain blank.
  • Place one Pico 2-pole tester probe on the HV negative test location and the other on the chassis ground. The two-pole tester display must remain blank.
  • Repeat step 4 to confirm the Pico 2-pole tester correctly displays a voltage if it is present.

Further guidance

Perform a 0 V potential test before working on any hybrid or electrical HV system, component or cable. If you leave the vehicle unattended, or move onto another task on the vehicle and then return, or move on to another HV component or cable, carry out a 0 V potential test before starting work.

For general information on the risks of working with hybrid and electric vehicles, please visit the Health and Safety Executive (HSE) motor vehicle repair website.

For further information on relevant qualifications and training, please visit the Institute of the Motor Industry Awards website.

Disclaimer

This help topic is subject to changes without notification. The information within is carefully checked and considered to be correct. This information is an example of our investigations and findings and is not a definitive procedure. Pico Technology accepts no responsibility for inaccuracies. Each vehicle may be different and require unique test settings.

`